Memmert - ICH 750, 115V - Stability Climate Chamber

Features
Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP - GCCP. ICH260ICH750 Memmert stability climate chambers guarantee the perfect atmosphere for climate and temperature tests.
- Stainless Steel: Scratch resistant, hygienic and durable.
- 2 Year Warranty: A limited 2 year warranty is included with the option to purchase an extra year.
- AtmoCONTROL: Create and monitor programs.
- TwinDISPLAY: Twice the features of SingleDISPLAY. Monitor programs easily via Ethernet or USB.
Specifications
Overview
-
Nominal Height:76.8" (195.07 cm)
-
Nominal Width:48.2" (122.43 cm)
-
Nominal Length:30.9" (78.49 cm)
-
Internal Height:47.2" (119.89 cm)
-
Internal Width:40.9" (103.89 cm)
-
Internal Length:23.6" (59.94 cm)
Temperature - Humidity
-
Setting Temperature without Range:-10 to +60 °C
-
Working Temperature Range with Humidity:10 to 60°C
-
Setting Accuracy Temperature:0.1°C
-
Temperature Sensor:2 Pt100 sensors DIN Class A in 4-wire-circuit
-
Humidity:Humidity supply with distilled water from external tank by self-priming pump
-
Humidification:By hot steam generator
Interior - Exterior - Control Technology
-
Stainless Steel Interior - Volume:749 L
-
Stainless Steel Interior - Max. Number of Internals:14
-
Stainless Steel Interior - Max. Loading per Internal:66 lbs / 30 kg
-
Stainless Steel Interior - Max. Loading of Chamber:440 lbs /200 kgs
-
Control Technology - ControlCOCKPIT:TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays.
-
Control Technology - Adjustable Parameters:Temperature (Celsius or Fahrenheit), fan speed, relative humidity, timer
-
Control Technology - Language Setting:German, English, Spanish, French, Polish, Czech, Hungarian
-
Control Technology - Timer:Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
-
Control Technology - Function SetpointWAIT:The process time does not start until the set temperature is reached
-
Control Technology - Calibration:Three freely selectable values each, temperature and humidity
Safety - Standard Equipment - Electrical Data
-
Safety - Autodiagnostic System:Integral fault diagnostics for temperature and humidity control
-
Safety - Alarm:Visual and acoustic
-
Standard Equipment - Door:Fully insulated stainless steel doors with 2-point locking (compression door lock)
-
Standard Equipment - Shelving:2 stainless steel grids, electropolished
-
Standard Equipment - Works Calibration Certificate:Standard values +10°C and +37°C, 60 % rh at +30°C
-
Electrical Data - Electrical Load:115 V (±10%), 50/60 Hz, Approx. 1350 W / 11.8 A
Downloads
-
Climate Chambers BrochureDownload
Useful Links
-
Data Sheet - Climate Chamber ICH750Visit Link