Features
High-precision control technology creates controlled and physiologically ideal surroundings for the perfect environment simulation in building physics, electronics, biology, zoology and botany. HCP50 Memmert climate chambers guarantee the perfect atmosphere for climate and temperature tests.
- Stainless Steel: Scratch resistant, hygienic and durable.
- 3 Year Warranty: A limited 2 year warranty is included with the option to purchase an extra year.
- AtmoCONTROL: Create and monitor programs.
- TwinDISPLAY: Twice the features of SingleDISPLAY. Monitor programs easily via Ethernet or USB.
Specifications
Overview
Temperature - Humidity
-
Working Temperature Range without Humidity:6°C up to +90°C
-
Setting Temperature Range:+18 to +90 °C
-
Setting Accuracy Temperature:0.1°C
-
Temperature Sensor:2 Pt100 sensors DIN Class A in 4-wire-circuit
-
Humidity Control:Active microprocessor control for humidifying and dehumidifying (20 - 95 % rh)
-
Setting Range Active Humidity Control:20 to 95 % rh and rh-Off
-
Setting Accuracy Humidity:0.5 % rh
Interior - Exterior - Control Technology
-
Control Technology - ControlCOCKPIT:TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays.
-
Control Technology - Adjustable Parameters:Temperature (Celsius or Fahrenheit), fan speed, relative humidity, timer
-
Control Technology - Language Setting:German, English, Spanish, French, Polish, Czech, Hungarian
-
Control Technology - Timer:Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
-
Control Technology - Function SetpointWAIT:The process time does not start until the set temperature is reached
-
Control Technology - Calibration:Three freely selectable values each, temperature and humidity
Safety - Standard Equipment - Electrical Data
-
Safety - Autodiagnostic System:Integral fault diagnostics for temperature and humidity control
-
Safety - Alarm:Visual and acoustic
-
Standard Equipment - Works Calibration Certificate:Works calibration certificate (measuring point chamber center) at 60°C with 75 % rh
-
Standard Equipment - Door:Fully insulated stainless steel doors with 2-point locking (compression door lock)
Downloads
-
Climate Chambers BrochureDownload
Useful Links
-
HCP ManualVisit Link