Features
HCP150 Memmert climate chambers guarantee the perfect atmosphere for climate and temperature tests.
- Stainless Steel: Scratch resistant, hygienic and durable.
- 3 Year Warranty: A limited 2 year warranty is included with the option to purchase an extra year.
- AtmoCONTROL: Create and monitor programs.
- TwinDISPLAY: Twice the features of SingleDISPLAY. Monitor programs easily via Ethernet or USB.
Specifications
Overview
-
Nominal Height:42.1" (106.93 cm)
-
Nominal Width:28.3" (71.88 cm)
-
Nominal Length:23.3" (59.18 cm)
-
Internal Height:27.6" (70.1 cm)
-
Internal Width:22" (55.88 cm)
-
Internal Length:15.7" (39.88 cm)
Temperature - Humidity
-
Working Temperature Range without Humidity:6°C up to +90°C
-
Setting Temperature Range:+18 to +90 °C
-
Setting Accuracy Temperature:0.1°C
-
Temperature Sensor:2 Pt100 sensors DIN Class A in 4-wire-circuit
-
Humidity Control:Active microprocessor control for humidifying and dehumidifying (20 - 95 % rh)
-
Setting Range Active Humidity Control:20 to 95 % rh and rh-Off
-
Setting Accuracy Humidity:0.5 % rh
Interior - Exterior - Control Technology
-
Stainless Steel Interior - Material:1.4301 (ASTM 304), corrosion resistant
-
Stainless Steel Interior - Volume:256 L
-
Stainless Steel Interior - Max. Number of Internals:10
-
Stainless Steel Interior - Max. Loading per Internal:33 lbs
-
Stainless Steel Interior - Max. Loading of Chamber:264 lbs
-
Control Technology - ControlCOCKPIT:TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays.
-
Control Technology - Adjustable Parameters:Temperature (Celsius or Fahrenheit), fan speed, relative humidity, timer
-
Control Technology - Language Setting:German, English, Spanish, French, Polish, Czech, Hungarian
-
Control Technology - Timer:Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
-
Control Technology - Function SetpointWAIT:The process time does not start until the set temperature is reached
-
Control Technology - Calibration:Three freely selectable values each, temperature and humidity
Safety - Standard Equipment - Electrical Data
-
Temperature Control:Mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature
-
Temperature Control:Over- and under temperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, adjustable at the controller
-
AutoSAFETY:Additionally integrated over- and under temperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or under temperature, heating is switched off in case of overtemperature, the compressor in case of under temperature
-
Autodiagnostic System:Integral fault diagnostics for temperature and humidity control
-
Alarm:With visual and acoustic alarm in case of over-/under temperature and under humidity, open door and empty water tank
-
Electrical Data:115 Volt, 50/60 Hz, approx. 15.7 A
Downloads
-
Climate Chambers BrochureDownload
Drawings
-
Sketch - HCP 150, 115VVisit Link
Useful Links
-
Data Sheet - Humidity Chamber HCP150Visit Link
-
Operating Manual - Humidity Chamber HCP150Visit Link