Portable top-loading autolaves with advanced safety and user-friendly features.

Product Range

SKU Name
HV-110 Amerex - HV-110 - Portable, Top-Loading Autoclaves Without Drying
HV-25 Amerex - HV-25 - Portable, Top-Loading Autoclaves Without Drying
HV-50 Amerex - HV-50 - Portable, Top-Loading Autoclaves Without Drying
HV-85 Amerex - HV-85 - Portable, Top-Loading Autoclaves Without Drying

Features

  • Space-saving design with lid opening upward.
  • Programmable auto-start for initiating a cycle up to 1 week later.
  • Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C.
  • Automatic air purging by a microprocessor prevents over-pressurization during a cycle.
  • One-touch lever to easily open and close chamber lid.
  • Programmable rate of steam exhaust.
  • Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.
  • In-process display shows status and progress of sterilization cycle.
  • Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.
  • Unique accessory: Floating sensor to monitor load temperature.
  • Sterilization timer is activated only when load temperature reaches set temperature.
  • Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up.
  • Memory backup system retains user-programmed parameters even in case of power failure.

Specifications

Overview

Technical Data

  • Temperature - Operating Range::
    105°C to 126°C/105°C to 135°C
  • Temperature - Display Range::
    128°C - 137°C
  • Temperature - Warming Range::
    45°C to 60°C
  • Gauge Pressure - Operating Range::
    3 to 30 psi (0.021 to 0.206MPa)/3 to 22 psi (0.02 to 148MPa)
  • Gauge Pressure - Maximum Allowable: :
    27 psi (0.186MPa)/38 psi (0.26MPa)
  • Sterilization Timer::
    1 to 250 minutes
  • Delayed Auto-Start Timer: :
    Program autoclave to start 1 minute to 7 days later
  • Accessories - Stainless Steel: :
    Mesh wire baskets, buckets (pails), and round test tube racks
  • Accessories - Factory or Field Installed: :
    Floating (load) sensor, digital printer, and data logger
  • Power Source::