Amerex - HV-110 - Portable, Top-Loading Autoclaves Without Drying

Features
The 110-liter (HV-110) Autoclave is a large, self-contained, portable floor models mounted on caster wheels. Equipped with a chamber 16.5” in diameter, it can accommodate significantly larger loads than 50-liter models. They are ideal for the sterilization of fermenters, media, wastes, and laboratory glassware. The HV-110 has a chamber that can handle any 10-liter fermenter, or even a 30-liter Bellco bioreactor which has a 16” diameter.
Space-Saving Design
Lid opens upward.
Programmable Auto-Start
For initiating a cycle up to 1 week later.
Dual-Sensing Lid Interlock
Prevents lid opening when chamber is pressurized or when temperature exceeds 97ºC.
Automatic Air Purging
By a microprocessor prevents over-pressurization during a cycle.
One-Touch Lever
To easily open and close chamber lid.
Programmable Rate
Of Steam Exhaust.
Door-Closure Sensor
Provides a prompt and the cycle will not start unless the door is closed properly.
In-process Display
Shows status and progress of sterilization cycle.
Agar Sterilization Mode
For sterilizing agar and then automatically maintaining it at liquid temperature.
Unique Accessory
Floating sensor to monitor load temperature.
Sterilization Timer
is activated only when load temperature reaches set temperature.
Agar Melting Mode
For rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up.
Memory Backup System
Retains user-programmed parameters even in case of power failure.
Safety Devices
Dual-sensing safety lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker.
Specifications
Overview
-
Nominal Height:46.5" (118.11 cm)
-
Nominal Width:26" (66.04 cm)
-
Nominal Length:25.6" (65.02 cm)
-
Capacity:110
Technical Data
-
Temperature:105ºC to 135ºC
-
Display Range:137ºC
-
Warming Range:45ºC to 60ºC
-
Agar Dissolution:Heating at 60ºC to 100ºC for up to 1 hour (temp. and time programmable), followed by 45ºC to 60ºC (temp. programmable) for up to 20 hours.
-
Operating Range Gauge Presure:3 to 30 psi (gauge), 0.021 to 0.21MPa
-
Maximum Allowable Gauge Presure:38 psi (gauge), 0.26MPa
-
Sterilization Timer:1 to 250 minutes
-
Delayed Auto-start:Program autoclave to start 1 minute to 7 days later
-
Overall Dimensions (W x D x H):(26 x 26 x 47) in, (66 x 65 x 118) cm
-
Chamber (Diameter x Height):110 liters, 16.5" x 31.3" (42 cm x 79.5 cm)
-
Source:208V/220V/240V, 50/60 Hz
-
Consumption Power:4000 watts (4000VA)
-
Shipping Weight:308 lb (140 kg)
-
Warranty:Autoclaves are protected by a 12 month limited warranty
Downloads
-
HV-Series 85-110 BrochureDownload