Memmert - I - Incubator

Product Range
| SKU | Name |
|---|---|
| IF 75, 230V | Memmert - IF 75, 230V - Forced Circulation Incubator |
| IF 30, 230V | Memmert - IF 30, 230V - Forced Circulation Incubator |
| IF 160, 230V | Memmert - IF 160, 230V - Forced Circulation Incubator |
| IN 750, 230V | Memmert - IN 750, 230V - Natural Convection Incubator |
| IN 750 Plus, 230V | Memmert - IN 750 Plus, 230V - Natural Convection Incubator |
| IN 110 Plus, 230V | Memmert - IN 110 Plus, 230V - Natural Convection Incubator |
| IN 260, 230V | Memmert - IN 260, 230V - Natural Convection Incubator |
| IN 260 Plus, 230V | Memmert - IN 260 Plus, 230V - Natural Convection Incubator |
| IN 450, 230V | Memmert - IN 450, 230V - Natural Convection Incubator |
| IN 160 Plus, 230V | Memmert - IN 160 Plus, 230V - Natural Convection Incubator |
| IN 55 Plus, 230V | Memmert - IN 55 Plus, 230V - Natural Convection Incubator |
| IN 30 Plus, 230V | Memmert - IN 30 Plus, 230V - Natural Convection Incubator |
| IN 75, 230V | Memmert - IN 75, 230V - Natural Convection Incubator |
| IN 450 Plus, 230V | Memmert - IN 450 Plus, 230V - Natural Convection Incubator |
| IN 110, 230V | Memmert - IN 110, 230V - Natural Convection Incubator |
| IN 75 PLUS 230V | Memmert - IN 75 PLUS 230V - Natural Convection Incubator |
| IN 55, 230V | Memmert - IN 55, 230V - Natural Convection Incubator |
| IF 750 Plus, 230V | Memmert - IF 750 Plus, 230V - Forced Circulation Incubator |
| IF 160 Plus, 230V | Memmert - IF 160 Plus, 230V - Forced Circulation Incubator |
| IN 160, 230V | Memmert - IN 160, 230V - Natural Convection Incubator |
| IF 450 Plus, 230V | Memmert - IF 450 Plus, 230V - Forced Circulation Incubator |
| IF 55 Plus, 230V | Memmert - IF 55 Plus, 230V - Forced Circulation Incubator |
| IF 260 Plus, 230V | Memmert - IF 260 Plus, 230V - Forced Circulation Incubator |
| IN 30, 230V | Memmert - IN 30, 230V- Natural Convection Incubator |
| IF 110 Plus, 230V | Memmert - IF 110 Plus, 230V - Forced Circulation Incubator |
| IF 450, 230V | Memmert - IF 450, 230V - Forced Circulation Incubator |
| IF 30 Plus, 230V | Memmert - IF 30 Plus, 230V - Forced Circulation Incubator |
| IF 75 Plus, 230V | Memmert - IF 75 Plus, 230V - Forced Circulation Incubator |
| IF 750, 230V | Memmert - IF 750, 230V - Forced Circulation Incubator |
| IF 260, 230V | Memmert - IF 260, 230V - Forced Circulation Incubator |
| IN 750 Plus, 115V | Memmert - IN 750 Plus, 115V - Natural Convection Incubator |
| IN 110 Plus, 115V | Memmert - IN 110 Plus, 115V - Natural Convection Incubator |
| IN 450 Plus, 115V | Memmert - IN 450 Plus, 115V - Natural Convection Incubator |
| IN 260 Plus, 115V | Memmert - IN 260 Plus, 115V - Natural Convection Incubator |
| IN 160, 115V | Memmert - IN 160, 115V - Natural Convection Incubator |
| IN 750, 115V | Memmert -IN 750, 115V - Natural Convection Incubator |
| IN 260, 115V | Memmert - IN 260, 115V - Natural Convection Incubator |
| IN 75 PLUS 115V | Memmert - IN 75 PLUS 115V - Natural Convection Incubator |
| IN 55 Plus, 115V | Memmert - IN 55 Plus, 115V - Natural Convection Incubator |
| IN 160 Plus, 115V | Memmert - IN 160 Plus, 115V - Natural Convection Incubator |
| IN 30 Plus, 115V | Memmert - IN 30 Plus, 115V - Natural Convection Incubator |
| IN 450, 115V | Memmert - IN 450, 115V - Natural Convection Incubator |
| IF 450 Plus, 115V | Memmert - IF 450 Plus, 115V - Forced Circulation Incubator |
| IF 750, 115V | Memmert - IF 750, 115V - Forced Circulation Incubator |
| IF 55 Plus, 115V | Memmert - IF 55 Plus, 115V - Forced Circulation Incubator |
| IN 30, 115V | Memmert - IN 30, 115V - Natural Convection Incubator |
| IF 750 Plus, 115V | Memmert - IF 750 Plus, 115V - Forced Circulation Incubator |
| IN 55, 115V | Memmert - IN 55, 115V - Natural Convection Incubator |
| IN 110, 115V | Memmert - IN 110, 115V - Natural Convection Incubator |
| IF 110 Plus, 115V | Memmert - IF 110 Plus, 115V - Forced Circulation Incubator |
| IF 260 Plus, 115V | Memmert - IF 260 Plus, 115V - Forced Circulation Incubator |
| IN 75, 115V | Memmert - IN 75, 115V - Natural Convection Incubator |
| IF 450, 115V | Memmert - IF 450, 115V - Forced Circulation Incubator |
| IF 160 Plus, 115V | Memmert - IF 160 Plus, 115V - Forced Circulation Incubator |
| IF 55, 115V | Memmert - IF 55, 115V - Forced Circulation Incubator |
| IF 110, 115V | Memmert - IF 110, 115V - Forced Circulation Incubator |
| IF 260, 115V | Memmert - IF 260, 115V - Forced Circulation Incubator |
| IF 30 Plus, 115V | Memmert - IF 30 Plus, 115V - Forced Circulation Incubator |
| IF 75 Plus, 115V | Memmert - IF 75 Plus, 115V - Forced Circulation Incubator |
| IF 75, 115V | Memmert - IF 75, 115V - Forced Circulation Incubator |
| IF 160, 115V | Memmert - IF 160, 115V - Forced Circulation Incubator |
| IF 30, 115V | Memmert - IF 30, 115V - Forced Circulation Incubator |
Features
Memmert incubator I
In the laboratory, the Memmert incubator I is ideal for all applications with temperatures up to +80 °C, specifically for incubating living cultures at +37 °C. Thanks to the finely tuned control technology, critical temperature overshoots are completely ruled out. Valuable loads are therefore warmed up particularly carefully in this highly precise microbiological incubator.
- Temperature range up to +80 °C
- 8 model sizes (32 to 749 litres volume)
- 2 model variants: SingleDISPLAY and TwinDISPLAY
- Natural convection or forced air circulation N/F
- Double doors (interior glass, exterior stainless steel) for a clear view without a drop in temperature
- Activation of sterilisation routine via ControlCOCKPIT (TwinDISPLAY)
Specifications
Overview
Temperature - Humidity
-
Resolution of Display for Setpoint and Actual Temperature Values:0.1°C
Interior - Exterior - Control Technology
-
Control Technology - Adjustable parameters:Temperature (Celsius or Fahrenheit), air flap position, program time, time zones, summertime/wintertime
-
Control Technology - ControlCOCKPIT:daptive multifunctional digital PID-microprocessor controller with high-definition TFT-color display
-
Control Technology - Timer:Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
-
Control Technology - Function SetpointWAIT:The process time does not start until the set temperature is reached
-
Control Technology - Language Setting:German, English, Spanish, French
-
Control Technology - Calibration:Three freely selectable temperature values
Safety - Standard Equipment - Electrical Data
-
Safety - Autodiagnostic System:For fault analysis
-
Standard Equipment - Door:Fully insulated stainless steel doors with 2-point locking (compression door lock)
-
Standard Equipment - Scope of Delivery:Incl. works calibration certificate for +37°C
-
Standard Equipment - Housing:Rear zinc-plated steel
Downloads
-
Incubators BrochureDownload
Useful Links
-
IF ManualVisit Link
-
IF Plus ManualVisit Link
-
IN ManualVisit Link
-
IN Plus ManualVisit Link































