American Biotech Supply - ABT-HC-PL-49 - 49 Cu. Ft. Premium Laboratory Glass Door Refrigerator

Features
This advanced unit consumes just 1.47 KWh per day while maintaining laboratory-grade temperature control, helping you reduce operational costs without compromising performance. The variable speed compressor technology automatically adjusts cooling output based on demand, delivering significant energy savings compared to traditional fixed-speed systems while operating at an impressively quiet 38 dBA or less.
The ABT-HC-PL-49 puts you in complete control of your temperature-sensitive materials with its sophisticated microprocessor-based PID controller and comprehensive alarm system. Battery backup ensures continuous monitoring even during power outages, while visual and audible alarms alert you to any temperature excursions, door ajar conditions, or system issues. The adjustable temperature range of 1°C to 10°C accommodates diverse storage requirements, and the LCD display provides clear, real-time temperature information at a glance.
Designed for maximum usability and longevity, the ABT-HC-PL-49 features double swing glass doors that open from either side for convenient access in any laboratory layout. Ten adjustable shelves with protective rear guard rails organize your specimens efficiently within the generous 49 cubic foot interior. The durable white powder coated steel construction and EPA-compliant high-density urethane foam insulation ensure years of reliable service, backed by an exceptional seven-year compressor warranty and two-year comprehensive coverage that demonstrates our confidence in this premium refrigerator’s quality.
Key Features
- Energy-efficient operation at 1.47 KWh per day with 465 BTU/hr average heat rejection
- Battery backup system maintains alarms and temperature monitoring during power failures
- Adjustable temperature range from 1°C to 10°C with PID microprocessor control
- EPA SNAP compliant R600a refrigerant with hermetic variable speed compressor
- RS-485 MODBUS communication and USB port for data transfer and updates
Benefits
- Slash energy costs while meeting sustainability goals with ultra-efficient 1.47 KWh/day consumption
- Protect valuable research materials with battery-backed monitoring that never sleeps
- Create a more pleasant work environment with whisper-quiet 38 dBA operation
- Simplify compliance documentation with built-in data logging and USB data transfer capabilities
- Maximize storage flexibility with ten adjustable shelves in a spacious 49 cubic foot capacity
- Reduce long-term ownership costs with a seven-year compressor warranty and durable construction
- Accelerate daily workflows with 70-minute pull-down time and convenient double-door access
- Ensure specimen integrity with ±1.2°C uniformity and ±1.0°C stability performance
Specifications
Overview
-
Nominal Height:81.5" (207.01 cm)
-
Nominal Width:54" (137.16 cm)
-
Nominal Length:35.75" (90.81 cm)
-
Internal Height:59" (149.86 cm)
-
Internal Width:49.13" (124.79 cm)
-
Internal Length:26.5" (67.31 cm)
-
Capacity:49
General Description and Application
-
Door:Double swing glass right and left hinged door(s)
-
Shelves:Ten adjustable shelves with guard rail on back
-
Drawers:Optional pull-out drawers available
-
Mounting and Installation:4 preinstalled swivel casters, front casters locking
-
Interior Lighting:Shielded, switched LED lighting, full coverage, balanced spectrum
-
Airflow Management:Forced Air technology, patent pending
-
External Probe Access:Rear wall port (3/4") dia.
-
Insulation:Cabinet is foamed-in-place with EPA compliant high density urethane foam
-
Exterior Materials:White powder coated steel
-
Access Control:Key Lock
-
General Warranty:Two (2) years parts and labor warranty
-
Compressor Warranty:Seven (7) years compressor warranty
-
Product Weight (lbs):581
-
Shipping Weight (lbs):700
-
Rated Amperage:4.5 Amps
-
Power Plug/Power Cord:NEMA 5-15 plug
-
Facility Electrical Requirement:110-120V AC
-
Agency Listing and Certification:ETL, C-ETL listed and certified to UL471 standard, hydrocarbon refrigerant safety, Energy Star Certified
Performance
-
Uniformity (Cabinet Air):±1.2
-
Stability (Cabinet Air):±1.0
-
Maximum Temperature Variation (Cabinet Air):±1.6
-
Stability (Simulator Ballast):Non-applicable
-
Stability (Simulator Bag):Non-applicable
-
Temperature Rise after Short Door Openings:Non-applicable
-
Recovery after Short Door Openings:Non-applicable
-
Energy Consumption (KWh/day):1.47
-
Average Heat Rejection (BTU/hr):465
-
Noise Pressure Level (dBA):38 or less installed
-
Pull Down Time to Nominal Operating Temp:70 min
Temp Controller
-
Controller Technology:Proportional integral derivative (PID) microprocessor with LCD display
-
Battery Backup:24V high-capacity battery, controller, all alarms active, temperature monitoring DAQ and event logging active on battery backup
-
Display Technology:Non-applicable
-
Digital Communication:RS-485 (MODBUS)
-
Data Transfer:USB port for data transfer and software updates
-
Chart Recorder:Non-applicable
-
Adjustable Temperature Range:1°C to 10°C
-
External Alarm Connection:State switching remote alarm contacts
-
Alarms:Alarm logging (last 100 entries) with Visual and audible indicators
-
Controller probe:Bottle with glass bead thermal media