Amerex - HVA-85 - Portable, Top-Loading Autoclaves with Cooling Fan and Advanced Safety and User-Friendly Features

Amerex - HVA-85 - Portable, Top-Loading Autoclaves with Cooling Fan and Advanced Safety and User-Friendly Features
Amerex - HVA-85 - Portable, Top-Loading Autoclaves with Cooling Fan and Advanced Safety and User-Friendly Features

Amerex - HVA-85 - Portable, Top-Loading Autoclaves with Cooling Fan and Advanced Safety and User-Friendly Features

Contact Brent for Assistance

Need help right away? Give our customer service team a call for immediate attention

(510) 909-5846
Brent Kolhede

Ask About This Item

Add the product to a quote to receive more information.

Ask an Expert

Economical, top-loading autoclaves (85L & 110L) with built-in fan for faster post sterilization cooling.

Features

The HVA-85 and HVA-110 models incorporate a 85-liter and a 110-liter chamber, respectively. They are self-contained, portable floor models mounted on caster wheels. Equipped with a chamber 16.5” in diameter, they can accommodate significantly larger loads than 50-liter models. They are ideal for the sterilization of fermenters, media, wastes, and laboratory glassware.

 

  • Space-saving design with lid opening upward.
  • Standard built-in cooling fan for faster post-sterilization cooling.
  • Dual lid safety interlock prevents lid opening when a cycle is in progress, the chamber is pressurized, or the temperature exceeds 97°C.
  • Agar sterilization mode sterilizes agar, and then automatically keeps it warm to prevent it from solidifying.
  • One-touch lever to easily open and close chamber lid.
  • Agar melting mode for rapidly melting agar and then automatically maintaining it at liquid temperature, or for a hot and faster start-up.
  • Door-closure sensor prevents a cycle from starting unless the door is closed properly.
  • In-process display shows the status and the progress of sterilization cycle.

Specifications

Overview

  • Nominal Height:
    39.4" (100.08 cm)
  • Nominal Width:
    26" (66.04 cm)
  • Nominal Length:
    25.6" (65.02 cm)

Technical Data

  • Temperature - Operating Range:
    105°C to 135°C
  • Temperature - Display Range:
    10°C to 137°C
  • Temperature - Agar Warming Range:
    After sterilization, agar can be maintained from 45°C to 60°C (programmable) toprevent coagulation for up to 20 hours.
  • Pressure - Max. Pressure (Gauge):
    0.26MPa
  • Pressure - Pressure Gauge Range:
    0.021 to 0.206MPa
  • Sterilization Timer:
    1 to 250 minutes
  • Dimensions - Chamber (D x H):
    85 liters, 16.5" x 24.2" (42.0 x 61.5 cm)
  • Options:
    Data logger
  • Power Source:
    208V/220V/240V, 50/60 Hz, single phase
  • Power Consumption:
    3000 watts (3000VA)
  • Shipping Weight:
    255 lb (116kg)