Amerex - AT-HRH-110 - Front-Loading Autoclave with Fully Automatic Drying Cycle Using Heat and Vacuum

Features
- Fully Automatic Operation from start to finish with or without drying.
- Self-contained Design does not require plumbing for set-up, in house steam, or a floor drain hole for steam exhaust.
- Cycles for Waste/Solid Loads with or without drying and a Liquid Cycle for media and agar.
- Pre-vacuum Cycle: Vacuum pump removesair from the chamber when sterilizing solids such as glassware and pipette tips, thereby eliminating cold spots, and ensuring faster and more efficient sterilization.
- Drying by Heat and Vacuum increases drying efficiency and reduces cycle times.
- Additional Drying Mode for complete drying without having to re-run the sterilization cycle.
- Delay Auto Start allows programming autoclave to start up to 7 days later.
- Large Internal Tank for water exhaust eliminates the need for a floor drain hole.
- Bacteria Filter reduces re-contamination.
- Auto Filling of Chamber - Convenient auto-filling from a 10-liter internal water tank.
- One-touch Door Closing Lever opens and closes the door easily, surely and safely.
- Door Safety Interlock prevents door from opening during a cycle, when the chamber is pressurized, and the temperature is above 97oC at which point super-heated liquids might boil over when disturbed.
- Door-closure Sensor prevents a cycle from starting unless the door is properly closed.
- Process Display shows the program selected and the status of the sterilization cycle.
- Chamber Dimensions: 16.5” diameter x 31.3” depth (420 mm x 795 mm), 110 liters.
Specifications
Overview
-
Nominal Height:54.5" (138.43 cm)
-
Nominal Width:27.2" (69.09 cm)
-
Nominal Length:45.3" (115.06 cm)
Technical Data
-
Self-Contained Design:Does not require in-house steam, plumbing or a floor drain hole for installation
-
Sterilization Temperature:105°C - 135°C (programmable)
-
Temperature Display Range:5°C - 137°C
-
Sterilization Timer:1 ~ 60 min (remaining time displayed)
-
Drying Timer:1 ~ 120 min (remaining time displayed)
-
Drying Method:Vacuum pump and heating
-
Chamber Water Source:Auto water filling from an internal 10L water tank
-
Maximum Allowable Pressure (Gauge Pressure):0.206 MPa (2.06 kg/cm2G)
-
Chamber Size (Diameter x Depth):110 liters, 16.5" x 31.3" (420 x 795 mm)
-
Chamber Material:Stainless steel SUS304
-
Pressure Gauge:Analog display
-
Standard Accessories:Drain hose, water supply hose, caster stopper
-
Power Source/Consumption:AC220V, 50/60Hz, 1 phase, 3.2kW
-
Net Weight (Approx.):462 lb, (210 kg)
-
Warrenty:1 year
Downloads
-