Beckman Coulter - B38619 - Avanti JXN-26 IVD Centrifuge, 200-240V, 50/60HZ, 24A

Beckman Coulter - B38619 - Avanti JXN-26 IVD Centrifuge, 200-240V, 50/60HZ, 24A

Beckman Coulter - B38619 - Avanti JXN-26 IVD Centrifuge, 200-240V, 50/60HZ, 24A

Contact Brent for Assistance

Need help right away? Give our customer service team a call for immediate attention

(510) 909-5846
Brent Kolhede

Your Zip Code: 000000

Change

Ask About This Item

Add the product to a quote to receive more information.

Ask an Expert
Experience simplified high-throughput sample processing and more control with the JXN-26 centrifuge with powerful high speed features, low heat output, imbalance tolerance and quiet performance. Has a maximum capacity of 6.0L and RPM of 26,000 (82,000 x g). The Friction Reduction System (FRS) means the machine runs quicker, quieter and cooler, with shorter cycle times with high-torque because of the exclusive Switched Reluctance (SR) drive. Stores up-to 1000 user-defined programs. This build of the JXN 26 is in vitro diagnostic (IVD) compatible.

Features

Experience simplified high-throughput sample processing and more control with the Avanti® JXN-26. Rely on the powerful features, improved imbalance tolerance, and quiet performance.

  • Monitoring and control flexibility with MobileFuge
  • Advanced, easy-to-use data management
  • Ergonomic design
  • Intuitive interface

 

Data Management Provides Traceability

 

  • Ideal for supporting numerous protocols in shared labs or GMP environments
  • Utilize data logging and real-time run graphing
  • Password protection for up to 50 unique user profiles
  • Network multiple instruments
  • Set up and store numerous protocols

 

Application Versatility

 

  • Temperature control is optimized ensuring sample quality and avoiding unwanted artifacts
  • Compatible with an extensive library of rotors, including fixed-angle and swinging bucket
  • Adaptable for numerous application and workflow needs – includes BioSafe system providing operator safety and sample protection
  • Broad labware range including Harvest Liners provide a complete sample protection solution

 

Safe and Sustainable

 

  • Dynamic Rotor Inertia Check (DRIC) and rotor recognition provide redundant safety checks to assure no rotor can be run above its rated speed
  • High-torque, Switched Reluctance (SR) drive cycle shortens cycle times
  • Uses less energy than traditional centrifuges

 

Easy to Use Software

 

  • Simultaneous display of set and actual run conditions
  • Rotor selection by name (not code)
  • 11 acceleration/12 deceleration rates
  • Delay start
  • Run times to 99:59, Hold, and ω2t integrator for applications requiring precise reproducibility

Specifications

Overview

  • Nominal Height:
    58.6" (148.84 cm)
  • Nominal Width:
    28" (71.12 cm)
  • Nominal Length:
    33.9" (86.11 cm)
  • Capacity:
    6

Technical Data

  • Platform:
    Avanti
  • Maximum Speed:
    26,000 rpm
  • Maximum g-Force:
    81,770 x g
  • BioSafe:
    Yes
  • Acceleration:
    11 acceleration profiles
  • Deceleration:
    12 profiles
  • Timed Run:
    Up to 99 hours, 59 minutes
  • Refrigeration System:
    Non-CFC, non-ozone depleting refrigerant
  • Temperature Range(s):
    From -10°C to +40°C in 1°C increments
  • Rotor ID:
    Automatic
  • Zonal Capability:
    Yes
  • Pollution Degree:
    2
  • Environmental Conditions:
    -10°C to 40°C in 1°C increments
  • Installation Category:
    II
  • Software:
    Virtual Network Computing (VNC), MobileFuge app for Apple iOS and Android
  • Material(s):
    Steel, Plastic
  • Finish:
    Powder Coat Paint
  • Weight:
    290 kg (639.3 lb)
  • Clearances:
    7.6 cm (sides) & 16 cm (rear)
  • Humidity Restrictions:
    80% (non-condensing)
  • Power Requirements:
    200-240 VAC, 50/60 Hz