Rephile - RG0E0050R - Genie E 5 EDI Pure Lab Water System with Tank Recirculation

Features
Genie E EDI Pure Water System produces EDI water (Type II water) from tap water directly. Resistivity of the product water is above 5 MΩ•cm at 25°C , which meets or exceeds Type II water quality as defined by ASTM, CAP, CLSI and ISO 3696 / BS 3997 and also complies with the purified water requirements from the European and U.S. Pharmacopoeia.
The system is CE/RoHS certified. RephiLe provides full documents support to meet user's GMP, GSP, GAP, GCP, GLP requirements.
Genie E System Includes:
- Main system
- Control Console
- RO membranes
- UV preinstalled
- Genie Cleaning Pack
Design & Functions
- The system can be linked to multiple dispensers via CAN cable or wireless. "1+N" Mode
- Exceptionally consistent and predictable high purity Type II water from the best-in-class EDI (electrodeionization) module
- Stable RO permeability over a wide range of temperatures on account of a temperature stabilization feedback function of the module
- An environmentally friendly In-line Mercury-free germicidal UV lamp is applied to kill bacteria
- A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink
- Leak protector incorporated can prevent damage from a water leakage by shutting the feed water off in case of unexpected leaking
- Tank recirculation model guarantees water quality in the tank
- Fully automated system has RO cleaning, pre-rinsing, flush and lots of other self-maintenance functions. The chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality
Effective TOC level controlment
- A tank sanitization module is equipped to effectively keep microbial growth at a lower level by LED UVC light
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation
- RFID tags ensure perfect placement of consumables and trace their performance
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor
- Signature verification for maintenance and service
Cartridges and Parts
1. EDI module
- Internal EDI module removes the remaining ions, further reduce the content of organic compounds and has a certain capacity to prevent the growth of bacteria from RO water
- Ion exchange resins are continuously regenerated by an electric field. No hazardous chemical regeneration or costly resin replacement is needed
- EDI module has a high degree of automation and minimal electricity consumption by using the equivalent of the energy
2. Cartridge
- Internal P Pack cartridge removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module
- AC Pack contains special activated carbon to remove organic impurities and free chlorines
3. Control console
- 8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen
- The control console can be placed on the bench or inside a drawer for further flexibility and space saving
- The console screen and dispenser screens are water-drop proof. You can operate the console and dispenser with latex gloves on
- The system has two level password protection on display menu for safety purposes
4. Dispenser
- The volumetric function can automatically deliver the water volume you need once it is set up
- With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute
- A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space
5. Final Filter
- Various final filters (optional) are applicable to ensure ultrapure water without particles, bacteria or pyrogen
6. Level sensor
- The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirement
- Water level and quality inside the tank can be viewed from the control console
Specifications
Overview
-
Nominal Height:21.3" (54.1 cm)
-
Nominal Width:8.3" (21.08 cm)
-
Nominal Length:17.3" (43.94 cm)
-
Internal Height:24" (60.96 cm)
-
Internal Width:8.3" (21.08 cm)
-
Internal Length:11.4" (28.96 cm)
Feed Water Requirements - Water Flow Rate
-
Tap Water:Municipal water, conductivity < 2000 μS/cm (1000 ppm)
-
Operating Temperature:5 - 35°C
-
Feed Water Pressure:1 - 6 bar (15 - 90 psi)
-
Water Production Rate (25°C):5 L/hr
-
Water Dispensing Rate:Up to 2.0 L/min
Product Water Quality
-
RO Rejection:97 to 98% ionic rejection (new RO cartridge), > 99% organic rejection, > 99% particulates & bacteria rejection
-
Water Resistivity (25°C):> 5 MΩ·cm (typically 10 - 16 MΩ·cm)
-
TOC:< 30 ppb
-
Product Water Quality Stored In Tank (for Tank Recirculation Models) - Resistivity (25°C):> 1 MΩ·cm (default), adjustable
Main System
-
Weight:20 kg
-
Input Voltage:110 - 240 VAC
-
Operating Voltage:24 VDC
-
Main System Power:< 200 W
Downloads
-