Memmert Compressor-Cooled Incubator ICP, 50/60 Hz, temperature range -12 to 60°C.

Features

Memmert ICP compressor-cooled incubator


The ICP compressor-cooled incubator delivers excellent results whenever rapid and precise changeover between heating and cooling phases in ramp operation is required. Thanks to the finely tuned control technology, temperatures reach the exact setpoint values without the need for energy-intensive bursts of power.


  • Temperature range -12°C up to +60°C
  • 4 model sizes (108 to 749 litres volume)
  • 1 model variant: TwinDISPLAY
  • Double doors as standard for all models for prevention of contamination and temperature drops, while providing an optimal view of sensitive loads through wide-area interior glass doors
  • Very good air circulation in the working chamber through sophisticated ventilation technology
  • Intelligent defrosting function

Specifications

Overview

Temperature - Humidity

  • Temperature Sensor:
    2 Pt100 sensors Class A in 4-wire-circuit
  • Working Temperature Range:
    From -12°C up to +60°C
  • Setting Accuracy Temperature:
    0.1°C

Interior - Exterior - Control Technology

  • Control Technology - Language Setting:
    German, English, Spanish, French
  • Control Technology - Function SetpointWAIT:
    The process time does not start until the set temperature is reached
  • Control Technology - Calibration:
    Three freely selectable temperature values
  • Control Technology - Adjustable Parameters:
    Temperature (Celsius or Fahrenheit), programme time, time zones, summertime/wintertime

Safety - Standard Equipment - Electrical Data

  • Safety - Autodiagnostic System:
    For fault analysis
  • Safety - Alarm:
    Audible and visual
  • Standard Equipment - Door:
    Fully insulated stainless steel doors with 2-point locking (compression door lock)
  • Standard Equipment - Internals:
    2 stainless steel grids
  • Standard Equipment - Scope of Delivery:
    Incl. works calibration certificate for +10°C and +37°C
  • Electrical Data - Electrical Load:
    115 V (±10%), 50/60 Hz, Approx. 10.4 amps