SKU Name
ICO 50K7, 115V Memmert - ICO 50K7, 115V - CO2 Incubator Including K7
ICO 150K7, 115V Memmert - ICO 150K7, 115V - CO2 Incubator Including K7
ICO 240K7, 115V Memmert - ICO 240K7, 115V - CO2 Incubator Including K7
ICO 105K7, 115V Memmert - ICO 105K7, 115V - CO2 Incubator Including K7
ICO 105, 230V Memmert - ICO 105 230V - CO2 Incubator
ICO 150, 230V Memmert - ICO 150 230V - CO2 Incubator
ICO 50, 230V Memmert - ICO 50 230V - CO2 Incubator
ICO 240, 230V Memmert - ICO 240 230V - CO2 Incubator
ICO 150, 115V Memmert - ICO 150, 115V - CO2 Incubator
ICO 240, 115V Memmert - ICO 240, 115V - CO2 Incubator
ICO 105, 115V Memmert - ICO 105, 115V - CO2 Incubator
ICO 50, 115V Memmert - ICO 50, 115V - CO2 Incubator

Features

Memmert CO₂ incubator ICO


The control system of the Memmert CO₂ incubator ICO is so finely tuned that the appliance reaches the setpoint temperature very quickly and without temperature overshoots. Alarm notifications to your mobile phone guarantee the safety of the chamber load. Ideal hygiene is a given as well: rounded edges enable easy and thorough cleaning, and the interior can be sterilised within 60 minutes at +180°C.


  • 4 model sizes (with a chamber volume of 56 to 241 litres)
  • Temperature range +18°C to +50°C
  • Setting range CO₂ 0 to 20 % CO₂
  • Setting range O₂ 1 to 20 % O₂
  • Setting range active humidity control (with option K7) 40 to 97 % and RH-off
  • Fail-safe, FDA-compliant logging of temperature, CO₂, O₂, humidity, and open door time data
  • Visual and acoustic alarm as well as alarm notification to mobile phones if individually adjustable temperature, CO₂, O₂, or humidity limits are exceeded
  • Active humidity control
  • The interior chamber, including all installations and sensors, can be sterilised at +180°C in a 60-minute programme

Specifications

Overview

Temperature - Humidity

  • Temperature Sensor:
    2 Pt100 sensors Class A in 4-wire-circuit
  • Working Temperature Range:
    5°C above ambient temperature up to +50°C
  • Standard Sterilization Program:
    60 minutes at 180°C (without removing the sensors)
  • Setting Temperature Range:
    +18 to +50°C
  • Setting Accuracy Temperature:
    0.1°C
  • Setting Accuracy Humidity:
    0.5% rh
  • Humidity Control (Standard):
    The Peltier element limits the value of relative humidity in the interior to 93% rh ±2.5%
  • Humidity Setting Range Active Humidity Control (with Option K7):
    Humidity supply with distilled water from external tank 40 to 97% rh and rh off

Interior - Exterior - Control Technology

  • Stainless Steel Interior - Material:
    1.4301 (ASTM 304), corrosion resistant
  • Stainless Steel Interior - Max. Loading per Internal:
    15 kg
  • Control Technology - ControlCOCKPIT:
    TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays
  • Control Technology - Language Setting:
    German, English, Spanish, French, Polish, Czech, Hungarian, Chinese
  • Control Technology - Function SetpointWAIT:
    The process time does not start until the set temperature is reached
  • Control Technology - Adjustable Parameters:
    Temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime/wintertime

Safety - Standard Equipment - Electrical Data

  • Safety - Alarm:
    Visual and acoustic
  • Standard Equipment - Internals:
    2 pcs stainless steel shelves, perforated, 1 pc stainless steel water dish
  • Standard Equipment - Housing:
    Rear zinc-plated steel
  • Standard Equipment - Door:
    Fully insulated stainless steel doors with 2-point locking (compression door lock)
  • Standard Equipment - Interior:
    Material 1.4301 (ASTM 304), corrosion resistant