Hettich - 420CELLCULTURE2-BC - Rotina 420 Benchtop Centrifuges, Cell Cuture Package 2 (Bio-Containment)

Features
The ROTINA 420 Cell Culture Package 2 BC comes complete with everything you need to perform your application. This includes the ROTINA 420 or ROTINA 420 R centrifuge, swing-out rotor, buckets and adapters for 15 mL and 50 mL tubes and bio-containment lids. Many a-la-carte options are also available.
This compact benchtop centrifuge has been developed for large sample volumes. It has a maximum capacity of 4 x 600 ml bottles, 140 blood tubes, 16 microtiter plates or 52 x 15 ml conical tubes, all on a single cost-effective rotor.
Best conditions for your application
Single-hand clamp lock for easy loading, unloading, transport and sealing.
The new generation of carrier buckets from the ROTINA 420 features an integrated handle to provide you with a convenient method for transporting and loading your samples while doubling as a locking mechanism for your bio-containment lids.
Highlights
- RPM: 50 - 15,000 min -1. Adjustable in increments of 10
- RCF: 50 - 24,400. Adjustable in steps of 1
- Max. capacity: 4 x 600 ml
- High-performance with fi rst-class equipment
- Choice of 5 rotors
- IVDR-conform according to regulation (EU) 2017/746
- Max. noise level of 51 dB(A) with rotor 4790-A
- Easy operation with keypad and control knob
- 98 program memories for more individuality
- 9 individual acceleration and 10 deceleration stages
- Model 420 R coolable from -20 to +40 °C with pre-cooling function
Features
- Metal housing and lid
- Viewing port in the lid
- Powered lid lock
- Lid dropping protection
- Emergency lid lock release
- Stainless steel chamber
- Automatic rotor recognition
- Brushless drive
- Error display
- Display in °C and °F possible
- Imbalance switch-off
- Backlit panel with actual values of all parameters
- Auditory message after completion of the centrifugation run
Areas of applications
Clinical chemistry, Hematology, Serology
HTP centrifuge suitable for large laboratories such as blood banks or high-throughput clinical labs.
Research and Industry, Cell culture, Assays
One rotor fits multiple flasks, bottles and plates, offering many options for cell culture and/or solid phase assays.
Facilities
- Hospitals
- Hematological labs
- Blood centers
- Veterinary labs
- Pharmaceutical labs
- Food analyzing labs
- Scientific labs in universities
Specifications
Overview
Technical Data
-
Voltage: 100 - 127 V 1 ~;Frequency: 50 - 60 Hz;Consumption: 900 VA;Emission, Immunity: FCC class B;Max. Capacity: 4 x 600 ml;Max. RPM: 15,000 min⁻¹;Max. RCF: 24,400;Running Time: 1 - 99 h 59 min 59s, ∞ continuous run, short cycle mode;Dimensions (W x D x H): 506 x 650 x 423 mm;Weight: approx. 84 kg;Noise Level: 51 dB (A) with rotor 4790-A:
Cell Culture Package - 2 - Bio-Containment
-
Tube Qty.:26 | 10
-
Volume (ml):15 Conical | 50 Conical
-
Size (mm):17 x 120 | 29 x 115
-
RPM:≤ 4,800
-
RCF:≤ 4,740, ≤ 4,688
Swing-out rotor, 4-place
-
Max. RCF:4,800
-
Max. RPM:4,740 min-1
-
Max. capacity:4 x 600 ml
-
Angle:90°
-
Standard equipment:Incl. Bio-Containment lid
-
Cat.No.:4784-A+4780+4783
Useful Links
-
Product OverviewVisit Link