Hematocrit 200 centrifuge, 120V, 60Hz.

Features

The HAEMATOKRIT 200 Hematocrit Package 24 comes complete with everything you need to perform your application. This includes the HAEMATOKRIT 200 centrifuge, hematocrit rotor, and a lid that functions as an evaluation disc.


Hematocrit determination in only 7 minutes


The HAEMATOKRIT 200 is a fast and efficient centrifuge for determination of the hematocrit count. It runs at 13,000 RPM and accommodates up to 24 capillary tubes to a maximum RCF of 16,060.


Results can be clearly viewed with the integrated Haematocrit reader in the rotor lid.


The HAEMATOKRIT 200 is a fast and efficient centrifuge for determining hematocrit count. It runs at 13,000 RPM and accommodates 24 capillary tubes to a maximum RCF of 16,060.


Highlights


  • RPM 200 - 13,000 min -1. Adjustable up to 10,000 RPM in increments of 10, above in increments of 100
  • Max. RCF 16,060
  • Compact, high-performance hematocrit centrifuge
  • IVD-conform according to directive 98/79/EC
  • Maximum noise level of ≤ 56 dB(A)
  • Impulse key for short cycle mode
  • 2 individual acceleration and deceleration stages
  • Easy operation with keypad

Features


  • plastic housing
  • metal lid
  • viewing port in the lid
  • one-hand lid lock
  • lid dropping protection
  • emergency lid lock release
  • light alloy chamber
  • brushless drive
  • error display
  • imbalance monitoring and switch-off
  • backlit panel with actual values of all parameters
  • 2 adjustable messages after completion of the centrifugation run (audio + visual)

Areas of applications


Clinical, Hematology & Oncology


Evaluation of the HCT by centrifugation is the highest standard which is necessary for the calibration of analyzers providing HCT values.


Facilities


  • Paediatrics in hospitals
  • Manufacturers of analyzing systems
  • Small hospitals

Watch the video

Specifications

Overview

Technical Data

  • Voltage: 100 - 127 V 1 ~;Frequency: 50 - 60 Hz;Consumption: 270 VA;Emission, Immunity: FCC class B;Max. Capacity: 24 capillaries;Max. RPM: 13,000 min-1;Max. RCF: 16,060;Running Time: 1 - 99 min, ∞ continuous run, short cycle mode (impulse button);Dimensions (WxDxH): 261 x 353 x 228 mm;Weight: approx. 10 kg;Max. Noise Level: ≤ 56 dB (A):