Yamato Scientific

ADL-311A

Features

  • Because this product applies heat on fine grain sample instantly and does not apply high temperature on dry fine powdersample itself, samples unstable to heat can be reliably changed into even fine powder
  • Prepared fine powder will not be oxidized and contains minimum water and is contamination-free
  • Drying is made directly from solution or suspension liquid sample into fine powder, which does not need pre- or post processes such as filtration, separation, or pulverization necessary in the conventional drying method and can be used without concern of contamination during a series of operations

Specifications

Item Code 212737
Model ADL-311A
Temp. adjusting unit setting range 40 to 220deg.C (inlet temperature), 0 to 60deg.C (outlet temperature)
Temperature adjusting accuracy Inlet temperature±1deg.C
Drying air amount adjusting range 0〜0.7m3/min
Spray air pressure adjusting range 0〜0.3MPa
Liquid sending pump flow rate range 0〜26 ml/min
Spray air line washing function Spraying at the nozzle tip, manual pulse jet system
External output Inlet temperature, outlet temperature, temperature outlet (4-20 mA)
Temperature adjusting device PID digital temperature adjusting device
Touch panel Blower, heater, liquid sending pump, pulse jet switch, error display
Control select switch Inlet temperature, outlet temperature control switch (Outlet temp. control is conditional.)
Temperature sensor K-thermocouple
Heater 2.0 kW (at 200V) to 2.88 kW (at 240V)
Liquid sending Fixed amount peristaltic pump
Spraying air pump Spraying air compressor (sold separately) is used
Service outlet For stirrer: AC100V, MAX2A
Suction blower Bypass blower
Filter Suction filter, exhaust filter
Recovery of solvent
Spray nozzle cooling mechanism Connector: nipple x 2, O.D.:φ10.5 mm
Spray air connection diameter Nipple diameter:φ7 mm
Spray air pressure Bourdon tube: 0.3 MPa
Exhaust connecting diameter φ50mm
Safety function Inlet/outlet temperature overheat, sample feed reverse rotation mechanism, over current electric leakage breaker, nozzle connection error
External dimensions(W×D×H mm) 580×420×1125mm
Power Source AC115/220VV
AC115/220V Single phase
Weight 80kg

Yamato Scientific

ADL-311SA

ADL-311SA

Features

  • ADL311SA: For aqueous soluble samples (When organic solvent is used, a GAS410 organic
    solvent recovery unit is required.)
  • Easy setup, easy operation
  • Suitable for heat sensitive samples. High heat is not
    directly applied to dry, fine powder
  • Obtain contaminant free fine powder which is not oxidized and contains minimal moisture
  • Direct drying of solution or solution liquid into fine powder. No pre- or post processes such as filtration, separation, or pulverization required
  • Safe and explosion free working is guaranteed in combination with GAS410 due to oxygen & pressure control
  • Easy operation with one-touch detachable mechanism for drying chamber and cyclone
  • An arm jack is equipped as standard for easy installation and removal of glassware attachments
  • A service outlet (max.2A) and a sample stand are equipped as standard for connecting a magnetic mixer for stirring suspended liquid samples
  • Unique peristaltic pump, nozzle cooling mechanism, pulse jet mechanism and a nozzle knocker for stable spray drying ADL311SA is highly mobile on wheels, or usable with shorter height as a bench top unit by removing the movable caster

Specifications

Item Code 212738
Model ADL-311SA
Temp. adjusting unit setting range 40 to 220°C (inlet temperature), 0 to 98°C (Outlet temperature)
Temperature adjusting accuracy Inlet temperature±1°C
Drying air amount adjusting range 0 to 0.7m3/min
Spray air pressure adjusting range 0 to 0.3MPa
Liquid sending pump flow rate range 0 to 26 mL/min
Spray air line washing function Spraying at the nozzle tip, Manual pulse jet system
External output Inlet temperature, Outlet temperature, Temperature outlet (4-20 mA)
Temperature adjusting device PID digital temperature adjusting device
Touch panel Blower, Heater, Liquid sending pump, Pulse jet switch, error display
Control select switch Inlet temperature, Outlet temperature control switch(Outlet temperature control is conditional)
Temperature sensor K-thermocouple
Heater 2.0kW (at200V) to 2.88kW (at240V)
Liquid sending Fixed amount peristaltic pump
Spraying air pump For water soluble samples air compressor is used (sold separately). For organic solvent samples the integrated compressor in GAS410 is used (No separate air compressor required).
Service outlet For stirrer: AC100V, MAX. 2A
Suction blower Bypass blower
Filter Suction filter, Exhaust filter
Recovery of solvent Solvent recovery unit GAS410 (Sold separately) is used
Spray nozzle cooling mechanism Connector: nipple×2, O.D.: ø10.5mm
Spray air connection diameter Nipple diameter: ø7mm
Spray air pressure Bourdon tube: 0.3 MPa
Exhaust connecting diameter ø50mm
Safety function Inlet / Outlet temperature overheat, Sample feed reverse rotation mechanism, Over current electric leakage breaker, Nozzle connection error
External dimensions(W×D×H mm) 580×420×1125mm
Power Source AC200-AC240V 16-18A
Single phase
Weight 80kg
Accessories Silicon tubes (with a stopper)×3, Exhaust duct (with one hose band)×1, Outlet temperature sensor, Spray air tube, Sample box, Static electricity removal earth, “Tetron” braided tube hose 5m (with two hose bands)