ESCO Airstream® Horizontal Laminar Flow Clean Bench
The Ultimate Energy-Efficient, Quiet, and Easy-to-Clean clean benches. Ideal for Plant Tissue Culture
Plant Tissue Culture is one of the most promising branch of plant science, occupying key positions in plant biotechnology, plant breeding and plant propagation. Among the many concerns in plant tissue culture, the sensitivity of its samples to any source of contamination highly influences its success. A single bacterial cell or fungal spore can be fatal to a small plant piece since it can easily contaminate the growth media. It is essential to maintain a sterile environment as much as possible to avoid the contamination of samples, and this can be provided by the use of a laminar flow cabinet.
Introducing Airstream® Horizontal Laminar Flow Cabinet, designed specifically for plant tissue culture. It offers a combination of smooth and easily cleanable work zone, easy-to-use features, superior filtration efficiency, and energy-efficient technology as part of Esco’s advocacy to produce environment-friendly laboratory equipment. Experience quality protection. Experience innovation.
Key Benefits:
- ISO Class 4 workzone
- Glass-enclosed workzone for unobstructed view
- Energy-efficient
- Low noise emission
Model No. | External Dimensions | Internal Dimensions | Airflow Velocity | Electrical |
LHG-4DS-F8 | 1300 x 1065 x 1105 mm (51.2″ x 41.9″ x 43.5″) |
1943 x 625 x 578 mm (76.5″ x 24.6″ x 22.8″) | 0.45 m/s (90 fpm) |
230 VAC 50/60 Hz |
LHG-4DS-F9 | 1300 x 1065 x 1105 mm (51.2″ x 41.9″ x 43.5″) |
1943 x 625 x 578 mm (76.5″ x 24.6″ x 22.8″) | 0.45 m/s (90 fpm) |
120 VAC 50/60 Hz |
ESCO Airstream® Gen 3 Laminar Flow Clean Benches
The Leading Solutions for Research Laboratories
More product variants and sizes to suit more applications and user preferences
Esco Airstream Horizontal Laminar Flow Clean Bench blends in latest laminar flow technology and innovation to provide proven protection for your samples and processes. Customers all over the world can now enjoy a plethora of laminar clean flow bench specification while enjoying the benefits of product protection. The new generation Airstream Horizontal Laminar Flow Clean Benches offers a wide range of options for our customers; with glass side wall, sizes from 3 to 6 feet, Behind the many options that the customer can select, the full range of the new Esco Airstream laminar flow clean benches is powered by the latest generation DC ECM motor. It is more efficient than legacy ECM and VFD motors. It now also offers ISO Class 3 workzone with 10x efficiency of its HEPA filters. With more choices for the customers, Esco laminar flow clean benches still offers the same level of product protection for your samples and processes where operator protection is not required.
Key Benefits:
- ISO Class 3 workzone
- Energy Efficient
- Superior airflow uniformity
- Array of cabinet specifications suited for your particular needs
Guide to Models (Airstream® LHG series) |
|||||
LHG – _ _ G – F _ |
|||||
Nominal Width |
Code |
Internal Height |
Code |
Electrical |
Code |
0.9 m (3 ft) |
3 |
2.0 ft. |
A |
220-240 VAC, 50/60 Hz |
8 |
1.2 m (4 ft.) |
4 |
2.5 ft. |
B |
110-130 VAC, 50/60 Hz |
9 |
1.5 m (5 ft.) |
5 |
3.0 ft. |
C |
|
|
1.8 m (6 ft.) |
6 |
|
|
|
|
Airstream® Polymerase Chain Reaction Cabinets
Polymerase Chain Reaction* (PCR) is a process where millions of copies of DNA are amplified from a single copy, or low copy number template. This reaction is fundamental to almost all applications requiring a high copy number of starting material and is used in all laboratories working with DNA and RNA.
Because of the high copy number generated during PCR, it is essential to prevent possible contamination of the PCR reaction. Precautions must be taken during the sample and reagent preparation steps to minimize this risk. In addition to good laboratory practice, the ideal PCR laboratory should consist of three areas, each isolated from the other. Reagents should be prepared in the reagent preparation area and transferred to the sample preparation area, through a pass box, or inside closed containers. After preparation of the final reaction mix, the tubes should be transferred to the amplification area, again through a pass box or in a closed container. The PCR amplification and results analysis takes place in this area.
To guarantee contaminant-free samples, it is essential to work in an environment where the air quality is controlled. This should form part of the equipment in the sample preparation area.
Key Benefits:
- HEPA-filtered laminar flow
- Airflow monitoring
- UV lamp & prefilter change alarm
Model No. | External Dimensions | Internal Dimensions | Laminar Airflow | Electrical |
PCR-3A1 | 1035 x 617 x 950 mm
(40.7″ x 24.3″ x 37.4″) |
935 x 538 x 550 mm
(36.8″ x 21.2″ x 21.7″) |
0.30 m/s
(60 fpm) |
230 VAC
50 Hz |
PCR-3A2 | 115 VAC
50/60 Hz |
|||
PCR-3A3 | 230 VAC
60 Hz |
|||
PCR-4A1 | 1340 x 617 x 950 mm
(52.8″ x 24.3″x 37.4″) |
1240 x 538 x 550 mm
(48.8″ x 21.2″ x 21.7”) |
230 VAC
50 Hz |
|
PCR-4A2 | 115 VAC
50/60 Hz |
|||
PCR-4A3 | 230 VAC
60 Hz |
Streamline® Polymerase Chain Reaction Cabinets
Polymerase Chain Reaction* (PCR) is a process where millions of copies of DNA are amplified from a single copy, or low copy number template. This reaction is fundamental to almost all applications requiring high copy number of starting material and is used in all laboratories working with DNA and RNA. Because of the high copy number that is generated during PCR, it is absolutely essential to prevent contamination of the PCR reaction.
In addition to good laboratory practice, the ideal PCR laboratory should consist of three areas, each isolated from the other. Reagents should be prepared in the reagent preparation area and transferred to the sample preparation area, through a pass box, or inside closed containers. After preparation of the final reaction mix, the tubes should be transferred to the amplification area, again through a pass box or in a closed container. The PCR amplification and results analysis takes place in this area. To guarantee contaminant-free samples, it is essential to work in an environment where the air quality is controlled, such as a PCR clean bench, vertical laminar flow or biological safety cabinet.
- HEPA-filtered laminar flow
- Cost & space saving
- Simple & Reliable operation
Model No. | External Dimensions | Internal Dimensions | Laminar Airflow | Electrical |
SCR-2A1 | 730 x 617 x 950 mm
(28.7” x 24.3” x 37.4”) |
630 x 538 x 550 mm
(24.8” x 21.2” x 21.7”) |
0.275 – 0.325 m/s
(54-64 fpm) |
230 VAC
50 Hz |
SCR-2A2 | 115 VAC
50/60 Hz |
|||
SCR-2A3 | 230 VAC
60 Hz |