{"title":"parent_8745074524388","description":null,"products":[{"product_id":"american-biotech-supply-ph-abt-hc-rfc12g-12-cu-ft-pharmacy-refrigerator-and-freezer-combination-with-glass-door","title":"American Biotech Supply - PH-ABT-HC-RFC12G - 12 Cu. Ft. Pharmacy Refrigerator and Freezer Combination with Glass Door","description":"\u003cp\u003eThe Premier Pharmacy Dual Temp Combination units feature separate microprocessor temperature controller allowing for precise temperature control, verification and recovery. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. Refrigerators Only.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAll models are equipped with digital temperature displays for convenient monitoring. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. The freezer units feature either an automatic or manual defrost operating system. For manual defrost freezers, periodic manual defrosting is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis model requires 4\" of clearance around back and sides of the unit for proper ventilation. Improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEnvironmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA\/SNAP mandates and UL, ASHRAE compliance guidelines.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDetails\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 probes; 1 in air and 1 in sample bottle, in both Refrigerator and Freezer\u003c\/li\u003e\n\u003cli\u003eSix adjustable shelves with guard rail on back to prevent product from being pushed against back wall, Refrigerator\u003c\/li\u003e\n\u003cli\u003eTwo adjustable shelves with guard rail on back to prevent product from being pushed against back wall, Freezer\u003c\/li\u003e\n\u003cli\u003eBottom footed shelf to allow air circulation, Refrigerator and Freezer\u003c\/li\u003e\n\u003cli\u003eForced draft circulation\u003c\/li\u003e\n\u003cli\u003eVaccine storage power cord warning label\u003c\/li\u003e\n\u003cli\u003eKeyed door locks\u003c\/li\u003e\n\u003cli\u003eMagnetic door gasket for positive seal\u003c\/li\u003e\n\u003cli\u003eIntegrated door handles\u003c\/li\u003e\n\u003cli\u003eLeveling legs\u003c\/li\u003e\n\u003cli\u003eStacking kit\u003c\/li\u003e\n\u003cli\u003eHFC-free refrigerant (R600a), foam insulation and packaging\u003c\/li\u003e\n\u003cli\u003ePharmacy refrigerator\/freezer toolkit and temperature logs\u003c\/li\u003e\n\u003cli\u003eTwo year parts and labor warranty, plus an additional three year compressor parts warranty\u003c\/li\u003e\n\u003cli\u003ePlease note this unit requires 2 outlets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTemp Controller\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor temperature controller, refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eDigital temperature display, refrigerator and freezer with battery back-up to support temperature monitoring and alarms\u003c\/li\u003e\n\u003cli\u003eAdjustable operating temperature range: Refrigerator: 36°F to 46°F (2°C to 8°C), Freezer: 5°F to -13°F (-15°C to -25°C)\u003c\/li\u003e\n\u003cli\u003eTemperature monitor device (TMD) complies with the current CDC guidelines, with 3 years certification of calibration, \"buffered\" probe in the product simulated solution, min\/max memory. F\/C switchable, field installable, and visual \u0026amp; audible temp alarm\u003c\/li\u003e\n\u003cli\u003eAudible and visual high and low temperature alarms, refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003e2 probes; 1 in air and 1 in sample bottle, in both Refrigerator and Freezer\u003c\/li\u003e\n\u003cli\u003eRemote alarm contacts, refrigerator and freezer\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"American Biotech Supply (ABS)","offers":[{"title":"Default Title","offer_id":48682505502948,"sku":"PH-ABT-HC-RFC12G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/8951\/5492\/files\/ph-abt-hc-rfc12g-ext-image_845fdf2b-d32a-4f30-b9e9-b3009f559b0d.jpg?v=1775648249"},{"product_id":"american-biotech-supply-ph-abt-hc-rfc12a-12-cu-ft-pharmacy-refrigerator-and-auto-defrost-freezer-combination","title":"American Biotech Supply - PH-ABT-HC-RFC12A - 12 Cu. Ft. Pharmacy Refrigerator and Auto Defrost Freezer Combination","description":"\u003cp\u003eThe Premier Pharmacy Dual Temp Combination units feature separate microprocessor temperature controllers allowing for precise temperature control, verification, and recovery. An interior fan-driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. Refrigerators Only.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAll models are equipped with digital temperature displays for convenient monitoring. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. The freezer units feature either an automatic or manual defrost operating system. For manual defrost freezers, periodic manual defrosting is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis model requires 4\" of clearance around the back and sides of the unit for proper ventilation. Improper installation will void the warranty and lead to temperature maintenance issues, overheating, and possible failure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDisclaimer: Auto defrost freezers incorporate an electric heater installed on the evaporator that assists in the removal of the frost and ice. Although the heater helps speed up the frost and ice removal, it can raise the temperatures within the freezer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C to 8°C) in the refrigerator and -58°F to 5°F (or -50°C to -15°C) in freezers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEnvironmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA\/SNAP mandates and UL, ASHRAE compliance guidelines.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDetails\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix adjustable shelves with guard rail on back to prevent product from being pushed against the back wall, Refrigerator\u003c\/li\u003e\n\u003cli\u003eTwo adjustable shelves with guard rail on back to prevent product from being pushed against the back wall, Freezer\u003c\/li\u003e\n\u003cli\u003eBottom footed shelf to allow air circulation, Refrigerator and Freezer\u003c\/li\u003e\n\u003cli\u003eForced draft circulation Refrigerator\u003c\/li\u003e\n\u003cli\u003eVaccine storage power cord warning label\u003c\/li\u003e\n\u003cli\u003eKeyed door locks\u003c\/li\u003e\n\u003cli\u003eMagnetic door gasket for positive seal\u003c\/li\u003e\n\u003cli\u003eIntegrated door handles\u003c\/li\u003e\n\u003cli\u003eLeveling legs\u003c\/li\u003e\n\u003cli\u003eStacking kit\u003c\/li\u003e\n\u003cli\u003eHFC-free refrigerant (R600a), foam insulation and packaging\u003c\/li\u003e\n\u003cli\u003ePharmacy refrigerator\/freezer toolkit and temperature logs\u003c\/li\u003e\n\u003cli\u003eTwo-year parts and labor warranty, plus an additional three-year compressor parts warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTemp Controller\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor temperature controller, refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eDigital temperature display, refrigerator and freezer with battery backup to support temperature monitoring and alarms\u003c\/li\u003e\n\u003cli\u003eAdjustable operating temperature range: Refrigerator: 36°F to 46°F (2°C to 8°C), Freezer: 5°F to -13°F (-15°C to -25°C)\u003c\/li\u003e\n\u003cli\u003eAuto defrost cycle every 6 hours:\n\u003cul\u003e\n\u003cli\u003eMax air temp in empty freezer: 4.34°C\u003c\/li\u003e\n\u003cli\u003eMax air temp in loaded freezer: -2.89°C\u003c\/li\u003e\n\u003cli\u003eMax sample temp in empty freezer: -4.76°C\u003c\/li\u003e\n\u003cli\u003eMax sample temp in loaded freezer: -9.58°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature monitor device (TMD) complies with the current CDC guidelines, with 3 years certification of calibration, \"buffered\" probe in the product simulated solution, min\/max memory. F\/C switchable, field installable, and visual \u0026amp; audible temp alarm\u003c\/li\u003e\n\u003cli\u003eAudible and visual high and low temperature alarms, refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003e2 probes; 1 in air and 1 in sample bottle, in both Refrigerator and Freezer\u003c\/li\u003e\n\u003cli\u003eRemote alarm contacts, refrigerator and freezer\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"American Biotech Supply (ABS)","offers":[{"title":"Default Title","offer_id":48878511587556,"sku":"PH-ABT-HC-RFC12A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/8951\/5492\/files\/ph-abt-hc-rfc12a-ext-image_3620f01b-fb29-40a6-84dd-faf1ca97dcad.png?v=1778044431"},{"product_id":"american-biotech-supply-ph-abt-hc-rfc12a-cad-12-cu-ft-premier-pharmacy-vaccine-refrigerator-and-freezer-combination-with-controlled-auto-defrost-freezer","title":"American Biotech Supply - PH-ABT-HC-RFC12A-CAD - 12 Cu. Ft. Premier Pharmacy\/Vaccine Refrigerator and Freezer Combination with Controlled Auto Defrost Freezer","description":"\u003cp\u003eOur patented \"Controlled Auto Defrost\" technology provides the convenience of an auto-defrost design while still ensuring that vaccines remain at consistent and stable temperatures below 5°F (-15°C).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe acceptable temperature ranges for vaccine storage are between 36°F and 46°F (2°C and 8°C) in the refrigerator and between -58°F and 5°F (-50°C and -15°C) in the freezer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDetails\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerator\/Freezer freestanding thermometer with 3-year certificate of calibration, with min\/max memory, °F\/°C switchable\u003c\/li\u003e\n\u003cli\u003eAudible and visual high and low temperature alarms for refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eRemote alarm contacts for refrigerator and freezer.\u003c\/li\u003e\n\u003cli\u003eSix adjustable shelves with guard rail on back to prevent product from being pushed against back wall (Refrigerator)\u003c\/li\u003e\n\u003cli\u003eTwo adjustable shelves with guard rail on back to prevent product from being pushed against back wall (Freezer)\u003c\/li\u003e\n\u003cli\u003eBottom footed shelf to allow air circulation (Refrigerator and Freezer).\u003c\/li\u003e\n\u003cli\u003eVaccine storage power cord warning label\u003c\/li\u003e\n\u003cli\u003eForced draft circulation (Refrigerator)\u003c\/li\u003e\n\u003cli\u003eKeyed door locks\u003c\/li\u003e\n\u003cli\u003eMagnetic door gasket for positive seal\u003c\/li\u003e\n\u003cli\u003eIntegrated door handles\u003c\/li\u003e\n\u003cli\u003eLeveling legs\u003c\/li\u003e\n\u003cli\u003eStacking kit\u003c\/li\u003e\n\u003cli\u003eTwo probe access ports (0.4\"); one for refrigerator and one for freezer\u003c\/li\u003e\n\u003cli\u003eWhite powder-coated exterior\u003c\/li\u003e\n\u003cli\u003eHFC-free refrigerant (R600a), foam insulation and packaging\u003c\/li\u003e\n\u003cli\u003ePharmacy refrigerator\/freezer toolkit and temperature logs\u003c\/li\u003e\n\u003cli\u003eTwo-year parts and labor warranty, plus an additional three-year compressor parts warranty\u003c\/li\u003e\n\u003cli\u003eCompatible with Pyxis®, Omnicell®, and AcuDose RX® systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTemp Controller\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor temperature controller for refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eDigital temperature display with sample simulated probe for refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eAdjustable operating temperature range: Refrigerator: 36°F - 46°F (2°C - 8°C), Freezer: 5°F - -13°F (-15°C - -25°C)\u003c\/li\u003e\n\u003cli\u003eDefrost:\n\u003cul\u003e\n\u003cli\u003eAuto defrost cycle every 6 hours (at Set Point -11°F \/ -24°C)\u003c\/li\u003e\n\u003cli\u003eMax air temp in empty freezer: 5°F (-15°C)\u003c\/li\u003e\n\u003cli\u003eMax air temp in loaded freezer: 3°F (-16°C)\u003c\/li\u003e\n\u003cli\u003eMax sample temp in empty freezer: 0°F (-18°C)\u003c\/li\u003e\n\u003cli\u003eMax sample temp in loaded freezer: -4°F (-20°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"American Biotech Supply (ABS)","offers":[{"title":"Default Title","offer_id":48682507075812,"sku":"PH-ABT-HC-RFC12A-CAD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/8951\/5492\/files\/ph-abt-hc-rfc12a-cad-ext-image.png?v=1775648286"},{"product_id":"american-biotech-supply-ph-abt-hc-rfc12ga-12-cu-ft-pharmacy-refrigerator-and-auto-defrost-freezer-combination-with-glass-door","title":"American Biotech Supply - PH-ABT-HC-RFC12GA - 12 Cu. Ft. Pharmacy Refrigerator and Auto Defrost Freezer Combination with Glass Door","description":"\u003cp\u003eThe Premier Pharmacy Dual Temp Combination units feature separate microprocessor temperature controllers allowing for precise temperature control, verification, and recovery. An interior fan-driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. Refrigerators Only.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAll models are equipped with digital temperature displays for convenient monitoring. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. The freezer units feature either an automatic or manual defrost operating system. For manual defrost freezers, periodic manual defrosting is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis model requires 4\" of clearance around the back and sides of the unit for proper ventilation. Improper installation will void the warranty and lead to temperature maintenance issues, overheating, and possible failure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDisclaimer: Auto defrost freezers incorporate an electric heater installed on the evaporator that assists in the removal of the frost and ice. Although the heater helps speed up the frost and ice removal, it can raise the temperatures within the freezer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C to 8°C) in the refrigerator and -58°F to 5°F (or -50°C to -15°C) in freezers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEnvironmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA\/SNAP mandates and UL, ASHRAE compliance guidelines.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDetails\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix adjustable shelves with guard rail on back to prevent product from being pushed against the back wall, Refrigerator.\u003c\/li\u003e\n\u003cli\u003eTwo adjustable shelves with guard rail on back to prevent product from being pushed against the back wall, Freezer.\u003c\/li\u003e\n\u003cli\u003eBottom footed shelf to allow air circulation, Refrigerator and Freezer.\u003c\/li\u003e\n\u003cli\u003eForced draft circulation Refrigerator.\u003c\/li\u003e\n\u003cli\u003eVaccine storage power cord warning label.\u003c\/li\u003e\n\u003cli\u003eKeyed door locks.\u003c\/li\u003e\n\u003cli\u003eMagnetic door gasket for positive seal.\u003c\/li\u003e\n\u003cli\u003eIntegrated door handles.\u003c\/li\u003e\n\u003cli\u003eLeveling legs.\u003c\/li\u003e\n\u003cli\u003eStacking kit.\u003c\/li\u003e\n\u003cli\u003eHFC-free refrigerant (R600a), foam insulation and packaging.\u003c\/li\u003e\n\u003cli\u003ePharmacy refrigerator\/freezer toolkit and temperature logs.\u003c\/li\u003e\n\u003cli\u003eTwo-year parts and labor warranty, plus an additional three-year compressor parts warranty.\u003c\/li\u003e\n\u003cli\u003ePlease note this unit requires 2 outlets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTemp Controller\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor temperature controller, refrigerator and freezer.\u003c\/li\u003e\n\u003cli\u003eDigital temperature display, refrigerator and freezer with battery backup to support temperature monitoring and alarms.\u003c\/li\u003e\n\u003cli\u003eAdjustable operating temperature range: Refrigerator: 36°F to 46°F (2°C to 8°C), Freezer: 5°F to -13°F (-15°C to -25°C).\u003c\/li\u003e\n\u003cli\u003eAuto defrost cycle every 6 hours:\n\u003cul\u003e\n\u003cli\u003eMax air temp in empty freezer: 4.34°C.\u003c\/li\u003e\n\u003cli\u003eMax air temp in loaded freezer: -2.89°C.\u003c\/li\u003e\n\u003cli\u003eMax sample temp in empty freezer: -4.76°C.\u003c\/li\u003e\n\u003cli\u003eMax sample temp in loaded freezer: -9.58°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature monitor device (TMD) complies with the current CDC guidelines, with 3 years certification of calibration, \"buffered\" probe in the product simulated solution, min\/max memory. F\/C switchable, field installable, and visual \u0026amp; audible temp alarm.\u003c\/li\u003e\n\u003cli\u003eAudible and visual high and low temperature alarms, refrigerator and freezer.\u003c\/li\u003e\n\u003cli\u003e2 probes; 1 in air and 1 in sample bottle, in both Refrigerator and Freezer.\u003c\/li\u003e\n\u003cli\u003eRemote alarm contacts, refrigerator and freezer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"American Biotech Supply (ABS)","offers":[{"title":"Default Title","offer_id":48878511751396,"sku":"PH-ABT-HC-RFC12GA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/8951\/5492\/files\/ph-abt-hc-rfc12ga-ext-image.png?v=1778044433"},{"product_id":"american-biotech-supply-ph-abt-hc-rfc12ga-cad-12-cu-ft-premier-pharmacy-vaccine-refrigerator-and-freezer-combination-with-controlled-auto-defrost-freezer-with-glass-door","title":"American Biotech Supply - PH-ABT-HC-RFC12GA-CAD - 12 Cu. Ft. Premier Pharmacy\/Vaccine Refrigerator and Freezer Combination with Controlled Auto Defrost Freezer with Glass Door","description":"\u003cp\u003eOur patented \"Controlled Auto Defrost\" technology provides the convenience of an auto-defrost design while still ensuring that vaccines remain at consistent and stable temperatures below 5°F (-15°C).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe acceptable temperature ranges for vaccine storage are between 36° Fahrenheit and 46° Fahrenheit (or between 2° Celsius and 8° Celsius) in the refrigerator and between -58° Fahrenheit and +5° Fahrenheit (or between -50° Celsius and -15° Celsius) in the freezer.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDetails\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerator\/Freezer freestanding thermometer with 3-year certificate of calibration, with min\/max memory, °F\/°C switchable\u003c\/li\u003e\n\u003cli\u003eAudible and visual high and low temperature alarms for both refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eRemote alarm contacts for refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eSix adjustable shelves with guard rail on back to prevent product from being pushed against back wall (Refrigerator)\u003c\/li\u003e\n\u003cli\u003eTwo adjustable shelves with guard rail on back to prevent product from being pushed against back wall (Freezer)\u003c\/li\u003e\n\u003cli\u003eBottom footed shelf to allow air circulation (Refrigerator and Freezer)\u003c\/li\u003e\n\u003cli\u003eVaccine storage power cord warning label\u003c\/li\u003e\n\u003cli\u003eForced draft circulation (Refrigerator)\u003c\/li\u003e\n\u003cli\u003eKeyed door locks\u003c\/li\u003e\n\u003cli\u003eMagnetic door gasket for positive seal\u003c\/li\u003e\n\u003cli\u003eIntegrated door handles\u003c\/li\u003e\n\u003cli\u003eLeveling legs\u003c\/li\u003e\n\u003cli\u003eStacking kit\u003c\/li\u003e\n\u003cli\u003eTwo probe access ports (0.4\"): one for refrigerator, one for freezer\u003c\/li\u003e\n\u003cli\u003eWhite powder-coated exterior\u003c\/li\u003e\n\u003cli\u003eHFC-free refrigerant (R600a), foam insulation, and packaging\u003c\/li\u003e\n\u003cli\u003ePharmacy refrigerator\/freezer toolkit and temperature logs\u003c\/li\u003e\n\u003cli\u003eTwo-year parts and labor warranty, plus an additional three-year compressor parts warranty\u003c\/li\u003e\n\u003cli\u003eCompatible with Pyxis®, Omnicell®, and AcuDose RX® systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTemp Controller\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor temperature controller for refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eDigital temperature display with sample simulated probe for refrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eAdjustable operating temperature range: Refrigerator: 36°F to 46°F (2°C to 8°C), Freezer:5°F to -13°F (-15°C to -25°C)\u003c\/li\u003e\n\u003cli\u003eDefrost:\n\u003cul\u003e\n\u003cli\u003eAuto defrost cycle every 6 hours (at Set Point: -11°F \/ -24°C)\u003c\/li\u003e\n\u003cli\u003eMax air temperature: Empty freezer: 5°F (-15°C), Loaded freezer: 3°F (-16°C)\u003c\/li\u003e\n\u003cli\u003eMax sample temperature: Empty freezer: 0°F (-18°C), Loaded freezer: -4°F (-20°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"American Biotech Supply (ABS)","offers":[{"title":"Default Title","offer_id":48682505535716,"sku":"PH-ABT-HC-RFC12GA-CAD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/8951\/5492\/files\/ph-abt-hc-rfc12g-cad-ext-image.png?v=1775648249"}],"url":"https:\/\/labequipco.com\/collections\/parent_8745074524388.oembed","provider":"Laboratory Equipment Company","version":"1.0","type":"link"}